Original Photo of BOP
Photo of BOP Disassembly
Housing Side Door Sealing Surface, Bore, Gate Chamber Cleaning an d Polishing Photos
Shell UT, MT, PT Flaw Detection Photos
Photos of Flaw Detection of Major Parts
Photos of Dimensional Measurement and Inspection Problems
Photos of Dimensional Measurement and Inspection Problems
The inspection found that the outer ring of the cylinder sealing groove fell off, there were pits on the sealing surface of the piston rod of the gate plate opening, and the sealing surface of the hydraulic locking cylinder was serious. Strain, piston, small cylinder sealing groove corrosion is serious.
Photos of Through-diameter Holes, Steel Rim Grooves Surfacing and Elimination and Machining Repair.
Photos of Major Parts Repair
Photo of the housing gate cavity and the sealing surface of the side door after repair.
Photo of the middle flange sealing surface after repair.
Photo of the cylinder head sealing surface after repair.
Photo of the main piston after repair
Photo after overlay welding and machining of small cylinder sealing groove
Photo of the small cylinder after repair
BOP backloading
Assembly Test and Completion Photos